  • Universal Friction & Wear Testing Machine

    Model MMW-1A - Jinan Testing Equipment IE Corporation

    The MMW-1A UTM for Friction Wear can simulate rolling, sliding and rolling & sliding combined movement under the certain contact pressure to complete point, line and plane simulating tests. The UTM for Friction Wear can be used to evaluate the friction wear performance of lubricant, metal, plastics, coating, rubber, and ceramics etc. The UTM for Friction Wear can not only satisfy the needs of traditional petrochemical industry to research, develop and inspect the various kinds of intermediate & high grade hydraulic oil, combustion engine oil and gear oil, but also can simulate evaluation on new material development and new technology research under dry condition.

  • Connect Generators to the Grid

    GridCode - DIgSILENT GmbH

    DIgSILENT has developed a new verification tool called DIgSILENT GridCode. The software has been designed in response to the need to verify whether a conventional or renewable power plant is compliant with local Grid Code interconnection requirements on basis of generating unit tests. There is a new trend towards verification of requirements at the point of interconnection of a power plant using transient stability simulations with numerical models. An increasing number of Transmission System Operators are including model validation methods to quantify the risk and uncertainty when using these simulation models in stability studies. These new methods have been included in the DIgSILENT GridCode tool.

  • Field Portable Wire Analyzer

    Model 2635 - DIT-MCO International

    The perfect tester for field use is rugged, mobile, and lightweight, without sacrificing the functionality and power of a larger system. That tester is found in the Model 2635. Weighing 32 pounds (14.5 kg), this wiring analyzer handles up to 400 test points of Series 10 switching per unit. The 2635 can be powered from any AC source 100-240 VAC or 28 VDC so you can use it anywhere in the world.

  • PNA-X Measurement Receiver for Antenna Test

    N5264B - Keysight Technologies

    A new industry standard for antenna test with 400,000 point per second data acquisition on all five measurement channels Twice as many receivers available compared to any other antenna receiver on the market Replace existing 8530A and 8360 solutions for a system speed improvement that is 10 times faster Built-in 8510/8530A code emulation software provides a drop-in replacement for existing antenna ranges utilizing an 8530A

  • 2 Pole 12 X 4 Low Thermal Relay Matrix Module

    DP-cPCI-4113 - Data Patterns Pvt. Ltd.

    A matrix is the most versatile switch topology. It is made up of rows and columns that connect any input to any output. With matrix switching system, it is easy to connect a number of instruments or sources to various test points of the UUT. The benefit of matrix switching is simplified wiring with which the overall test system can easily and dramatically change the internal connection paths without any manual intervention.DP-cPCI-4113 offers switching matrix in a single slot 6U sized cPCI module with flexibility to configure for 48 cross-points or 72 cross-points on factory selectable basis.

  • Penetrometers

    PCE Instruments

    Penetrometers measure the firmness or hardness of fruit. Penetrometers are ideal for determining the best time to harvest fruit or to test its progress to maturity. The firmness of fruit is one of the most widely used parameters in testing its maturity, together with measuring the fruits sugar content using refractometers. Electronic penetrometers come with different diameter penetration points. This allows for fruit of different size and hardness to be tested. It is important that this first part of the measurement process is done correctly if the readings obtained are to be valid in making adequate decisions as to when the fruit should be harvested. It is important the the samples that are measured are representative of the entire crop, considering a sufficient minimum quantity sample, size and quality.

  • SWB-2816, 8x46, 0.3 A, Row Access, Reed Relay Matrix Module for SwitchBlock

    781420-16 - NI

    8x46, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2816 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, … individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock

    781420-14 - NI

    8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock

    781421-14 - NI

    8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2817, 16x22, 0.3 A, Reed Matrix Module for SwitchBlock

    781421-17 - NI

    16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2812, 16x9, 1 A, Reed Matrix Module for SwitchBlock

    781420-12 - NI

    16x9, 1 A, Reed Matrix Module for SwitchBlock - The SWB‑2812 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2817, 16x22, 0.3 A, Reed Matrix Module for SwitchBlock

    781420-17 - NI

    16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2812, 16x9, 1 A, Reed Matrix Module for SwitchBlock

    781421-12 - NI

    16x9, 1 A, Reed Matrix Module for SwitchBlock - The SWB‑2812 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2816, 8x46, 0.3 A, No Row Access, Reed Relay Matrix Module for SwitchBlock

    781421-16 - NI

    8x46, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2816 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2834, 8x34, 2 A, Electromechanical Relay Matrix Module for SwitchBlock

    781420-34 - NI

    8x34, 2 A, Electromechanical Relay Matrix Module for SwitchBlock - The SWB‑2834 is an electromechanical relay matrix card for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.